Zum Inhalt springen
Esc
↑↓navigieren↵öffnen⌘Jvorschau

Classification

How nap-tool classifies a harmonized grid-measure table, which rows it drops, and which columns it derives.

uv run nap-tool classify --scheme-id <id> [--set-id <id>] (or Run classification in the UI) reads the harmonized table of a grid-measure set and writes a new generation $NAP_DATA_DIR/classified/set_<set>/.versions/scheme_<scheme>_<uuid>/. The generation named in classified/set_<set>/scheme_<scheme>.current is the current output (ADR-0006). Each generation holds:

  • classified.csv: every source column unchanged, plus the derived columns below.
  • validation_report.md / .json: metrics, flag counts, quality grades, dropped rows.
  • unmapped_values.csv: vocabulary values without a mapping (dso_slugs comma-separated).

The rules are deterministic and live in config/classify.yaml; config/classify_<year>.yaml is picked automatically for a single-year set. Patterns applied to case-folded text must use ss instead of ß (the config check rejects ß).

Dropped rows

Footer, licence and blank rows are not measures. A row is dropped (and listed under dropped_rows in the report) if none of record_type.identity_fields is filled, or if fewer than record_type.min_filled_fields content fields (all fields except record_type.metadata_fields) are filled. Overview rows are always kept.

Derived columns

Identifiers keep their names: row_id, nap_round, document_date, dso_name, dso_mastr_nr, dso_bdew_code. Everything classified or inferred has the prefix inferred_. List values are comma-separated.

Column Content
inferred_record_type measure, collective (Sammler, pauschal, Kleinstmaßnahmen, Maßnahmenregion …) or overview
inferred_project_category, inferred_project_status, inferred_permit_status, inferred_primary_driver, inferred_existing_bottleneck, inferred_forecast_bottleneck vocabulary codes of the source columns
inferred_measure_type normalized project category; from name/description if the column is empty
inferred_asset_type primary asset type, see below
inferred_asset_types all asset types, primary first
inferred_asset_class line, station or other of the primary type
inferred_grid_level grid levels EHV, EHV/HV, HV, HV/MV, MV, MV/LV, LV (or all): the reported level first, then the levels of the asset codes; from the text only if both are missing
inferred_voltage nominal voltage in V per grid level, aligned with inferred_grid_level; upper/lower for transformation levels; an unknown entry stays empty (MV,LV → ,400)
inferred_line_capacity_change_mva, inferred_station_capacity_change_mva capacity change by asset class
inferred_location_start, _end, _via locations as written in the source; end and via points only for lines
inferred_location_start_kind, _end_kind substation, switching_station, local_substation (station keyword before the name), search_area, street_address, code or place
inferred_object_ref line, plant and station IDs (Bl. 2473, N1, UW93)
inferred_quality_classification high, medium (asset type from description or codes, level from text), low (asset type or level missing, level conflict) or none
inferred_quality_location high, medium (from description, split by hyphen or underscore route, several stations, line end missing), none or not_applicable (collective, reference rows)
inferred_flags quality and data flags, e.g. asset_type_from_codes, grid_level_conflict, voltage_inferred, location_source:measure_name, implausible:line_length_km, unresolved:planned_start, unmapped:grid_level, duplicate_of=<row_id>

Asset types

substation, switching_station, local_substation, overhead_line, cable, line_or_cable (line type unknown), transformer, switchgear, reactive_power_compensation, earth_fault_compensation, voltage_regulator, line_component, secondary_tech, grid_connection, network (only when nothing more specific is named), other.

Sources in order: free-text asset_type cell (NAP 2024), measure name, description, then the NAP 2026 asset codes (asset_codes in the YAML):

Code Asset type Grid level
201 substation EHV/HV
301 line_or_cable HV
302 line_component HV
401 substation HV/MV
501 line_or_cable MV
601 local_substation MV/LV
701 line_or_cable LV
801 secondary_tech
802 reactive_power_compensation

Codes add their asset types when the text names no asset of the same class. Among code-derived types, the code on the reported grid level comes first. When the text only names two or more stations as route ends (“ST A > ST B”) and a code says line, the line comes first. Cable designations (NKBA, NA2XS(F)2Y, NAYY …) count as cable.

inferred_voltage takes a single explicit voltage from the text even when it lies on another level than the reported one (flag voltage_other_level). line_or_cable is refined to overhead_line or cable by line_construction_type (Freileitung, Erdkabel).

Zuletzt aktualisiert am